Vaisala MMT310 Moisture & Temperature Meter Series

Features

  • Continuous measurement of moisture in oil
  • Proven Vaisala HUMICAP sensor, over 15 years in oil applications
  • Measurements in lubrication, hydraulic and transformer oils
  • Excellent pressure andtemperature tolerance
  • Measuring water activity – ppm calculation for transformer oil
  • Small size, easy to integrate
  • Traceable calibration for measurement and analog outputs (certificates included)
Enquiry

Dpstar is a leading supplier of environmental measurement sensors for temperature, relative humidity, pressure, dew point, CO2, and other environmental condition monitoring for industrial process application and research. Since the ’90s, we earned a reputation as a trusted partner to our clients through our commitment and dedication. We are an authorized distributor and supplier of measuring sensors solutions from renowned manufacturers Vaisala. Vaisala is a global leader in environmental and industrial measurement. Building on 80 years of experience, Vaisala provides observations for a better world. Vaisala is a reliable partner for customers around the world, offering a comprehensive range of innovative observation and measurement products and services.

The MMT310 series incorporates the latest generation of the Vaisala HUMICAP sensor, developed for demanding moisture measurement in liquid hydrocarbons. The sensor’s excellent chemical tolerance provides accurate and reliable measurement over the wide measurement range. Vaisala HUMICAP Moisture and Temperature Transmitter Series for Oil MMT310 is a fast and reliable online detector for moisture in oil.

MMT310 measures moisture in oil in terms of the water activity (aw) and temperature (T). Water activity indicates directly whether there is a risk of freewater formation. The measurement is independent of oil type, age, and temperature.

Dimension

Key Benefits

Fast
Online, real-time detection of moisture in oil without sampling.

Easy to install and operate
Installation through ball valve. No need to shut down the process.

Reliable
Tells the true margin to water saturation point in all changing conditions, taking into account e.g. temperature changes and aging of oil.

Applications

MMT310 can be used in lubrication and hydraulic systems as well as in transformers. It can be used for on-line moisture monitoring and as a control function, allowing separators and oil purifiers to be started only when necessary.

Specification

Measurement Performance
Water Activity
Measurement range aw (%RS) 0 … 1 (0 … 100 %)
Accuracy (Including Non-Linearity, Hysteresis, and Repeatability):
0 … 0.9 (0 … 90 %)
0.9 … 1.0
±0.02
±0.03
Response time (90 %) at +20 °C in still
oil (with stainless steel filter)
10 min
Sensor Vaisala HUMICAPâ 180L2
Temperature
Measurement range (-40 … +180 °C) (-40 … +356 °F)
Typical accuracy at +20 °C (68 °F) ±0.2 °C (±0.36 °F)
Sensor Pt100 RTD Class F0.1 IEC 60751
Mechanical Specifications
IP rating IP66
Weight example: MMT317 with 2 m
cable (Weight depends on selected probe
and cable)
476 g
Cable feed through alternatives 8-pole connector with 5 m cable Female 8-pin connector screw joint for cable diameter 4 … 8 mm
Sensor protection Stainless steel grid standard filter
Stainless steel grid filter for high flow rates (> 1 m/s)
Materials
Transmitter housing G-AlSi 10 Mg
Transmitter base PPS
Probe Cable Length
MMT317 2 m, 5 m, or 10 m
MMT318 2 m, 5 m, or 10 m
Probe installation MMT317
Swagelokâ NPT 1/2″, ISO 3/8″ or ISO 1/2″
Probe installation MMT318
Fitting bodies ISO 1/2″, NPT 1/2″
Spare Parts and Accessories
Rain shield ASM211103
USB cable 238607
Stainless steel filter HM47453SP
Stainless steel filter (high flow rate) 220752SP
Ball-Valve Set BALLVALVE-1
Operating Environment
Operating temperature for electronics (-40 … +60 °C) (-40 … +140 °F)
Storage temperature (-55 … +80 °C) (-67 … +176 °F)
Pressure range for MMT318 with ballvalve
up to 120 °C
0 … 40 bar
Pressure range for MMT317 0 … 10 bar
EMC compliance EN61326-1, Industrial environment
Inputs and Outputs
Two analog outputs, selectable and scalable 0 … 20 mA or 4 … 20 mA
0 … 5 V or 0 … 10 V
1 … 5 V available through scaling
Typical accuracy of analog output at +20 °C ±0.05 % full scale
Typical temperature dependence of analog output 0.005 %/˚C (0.003 %/°F) full scale
Serial output RS-232C
Connections 8-pole connector with RS232C, current/ voltage outputs (two channels) and Uin
Operating voltage 10 … 35 VDC
External load RL < 500 Ω
Startup time after power-up 3 s
Minimum Operating Voltage
RS232C output 10 VDC
Analog output 15 VDC
Pressures above 10 bara (145 psia) 24 VDC
Power Consumption
RS232C 12 mA
Uout 10 V (10 kΩ) Channel 1 & channel 2 12 mA
Iout 20 mA (load 511 Ω) Channel 1 & channel 2 50 mA

Download

Vaisala-MMT310-Moisture and Temperature Meter Series_DpstarGroup

Reviews

There are no reviews yet.

Be the first to review “Vaisala MMT310 Moisture & Temperature Meter Series”