Features

  • Industry-leading precision and accuracy
  • Printed reports for any time period
  • 10-year battery
  • Validation and continuous monitoring with the same model
  • Two-year limited warranty
  • Superior alternative to chart recorders and hard-wired systems
  • Timebase calibrated over the operating temperature range
  • Adjustable time based recording
  • Snap-in logger cradle for easy network connectivity
  • Two probe options give high accuracy – from -90 °C to +70 °C
  • Traceable to SI units through national metrology institutes.
Enquiry

Dpstar is a leading supplier of environmental measurement sensors for temperature, relative humidity, pressure, dew point, CO2, and other environmental condition monitoring for industrial process application and research. Since the ’90s, we earned a reputation as a trusted partner to our clients through our commitment and dedication. We are an authorized distributor and supplier of measuring sensors solutions from renowned manufacturers Vaisala. Vaisala is a global leader in environmental and industrial measurement. Building on 80 years of experience, Vaisala provides observations for a better world. Vaisala is a reliable partner for customers around the world, offering a comprehensive range of innovative observation and measurement products and services.

The 1000/1400 temperature data loggers include the VL series for regulated environments and the SP series for non FDA/GxP regulated industries. The VL series of data loggers, together with vLog VL software, provide a superior, high accuracy solution for use in FDA/GxP regulated environments by ensuring tamperproof files and electronic records that meet 21 CFR Part 11 requirements. The 1000/1400 temperature data loggers include calibrations traceable to SI units through national metrology institutes.3) The SP‑series provides a compact, easily deployable, highly accurate measurement and recording device. Coupled with vLog SP software for downloading, displaying, analyzing and reporting of recorded environmental data, the SP‑series was designed for use in non FDA/GxP regulated environments. Optional browser‑based viewLinc software provides 24/7 multi‑stage alarm notification and remote monitoring for both the VL and SP series of data loggers.

Applications

The 1000/1400 temperature data loggers are ideal for monitoring and validation of:

  • Refrigerators and freezers (to -90 °C)
  • Incubators
  • Stability Chambers
  • Warehouses
  • Ambient conditions

Autonomous Power and Recording Capacity

Each data logger contains a 10-year battery and onboard memory for recording at the point of measurement. With autonomous power and recording capacity, data is immune to network and power interruptions. 3)

3) Measurement results are traceable to the international system of units (SI) through national metrology institutes (NIST USA, MIKES Finland, or equivalent) or ISO/IEC 17025 accredited calibration laboratories

Key Benefits

  • Long-life battery and large onboard memory
  • Flexible connectivity and interoperability
  • Stable, accurate measurements

Specification

General
Interfaces RS-232 serial, USB, Ethernet,
WiFi, PoE network interface available
PC software Graphing & Reporting Software
vLog SP for SP series
vLog VL for VL series
viewLinc for continuous monitoring and alarming
OPC Server to add on to existing OPC compatible monitoring systems
Internal clock Accuracy ±1 min/month
-25 °C … +70 °C
(-13 °F … +158 °F)
Logger operating / Storage range -40 °C … +85 °C (-40 °F … +185 °F)
0 … 100 %RH non-condensing
Power source Internal 10-year lithium battery (Battery life specified with sample interval of 1 min or longer)
Electromagnetic compatibility FCC Part 15 and CE
EN 50581:2012
EN 55032:2012/AC:2013 Class B
EN 61326-1:2013
RoHS compliance 2011/65/EU
Mechanical Specifications
Size 85 × 59 × 26 mm (3.4 × 2.3 × 1 in)
Weight 76 g (2.7 oz)
Mounting 3M Dual Lock™ fasteners
Snap-in connector locks provide secure probe connections
Internal Temperature Sensor
1000-21x series Precision-tolerance epoxy-encapsulated NTC thermistor
Memory
1000-2XX series 48 100 12-bit samples
1400-44X series 85 300 12-bit samples
Memory type Non-volatile EEPROM
Memory modes User selectable: wrap (FIFO) or stop when memory is full. User selectable start time. User selectable stop time (VL‑series only).
Sampling rates User-selectable (in 10 second intervals) from once every 10 seconds to once a day.
Recording Span: 1000-2xx
Number of Channels Enabled
Sample Interval 1 2
10 seconds 5.5 days 2.7 days
1 minute 1.1 months 16.7 days
5 minutes 5.5 months 2.7 months
15 minutes 1.3 years 8.3 months
1 hour 5.4 years 2.7 years
Recording Span: 1400-44x
Number of Channels Enabled
Sample Interval 1 2 3 4
10 seconds 9.8 days 4.9 days 3.2 days 2.4 days
1 minute 1.9 months 29.6 days 19.7 days 14.8 days
5 minutes 9.8 months 4.9 months 3.2 months 2.4 months
15 minutes 2.4 years 1.2 years 9.8 months 7.4 months
1 hour 9.7 years 4.8 years 3.2 years 2.4 years
EPT Series Temperature Probes
Sensor Models
“N” range external probes EPT-23N-XXN and EPT-22W-XXN
Operating/storage range -40 °C … +95 °C (-40 … +203 °F)
Connector color code Black
“V” range external probes EPT-23N-XXV and EPT-22W-XXV
Operating/storage range -95 °C … +95 °C (-139 … +203 °F)
Connector color code Blue
Sensor Tips
EPT-23N-XXX Stainless steel
Diameter 3.2 mm (0.13 in)
Length 38 mm (1.5 in)
EPT-22W-XXX (liquid submersible) Sealed teflon tip
Diameter 3 mm (0.12 in)
Length 28 mm (1.1 in)
Probe lengths 3 m (10 ft) and 7.6 m (25 ft)
Cable construction 2 mm (0.08 in) diameter Teflon coated cable
Temperature Range and Accuracy
Internal Sensor
Calibrated measurement range -25 … +70 °C (-13 … +158 °F)
Operating/storage range -40 … +85 °C (-40 … +185 °F)
0 … 100 %RH non-condensing
Initial accuracy ±0.10 °C over +20 … +30 °C
(±0.18 °F over +68 … +86 °F)
±0.20 °C over -25 … +70 °C
(±0.36 °F over -13 … +158 °F)
One year accuracy ±0.15 °C over +20 … +30 °C
(±0.27 °F over +68 … +86 °F)
±0.25 °C over -25 … +70 °C
(±0.45 °F over -13 … +158 °F)
External Probes – All Models
N Range External Probe
Calibrated measurement range -25 … +70 °C (-13 … +158 °F)
Operating/storage range -40 … +95 °C (-40 … +203 °F)
Initial accuracy 1) ±0.10 °C over +20 … +30 °C
(±0.18 °F over +68 … +86 °F)
±0.15 °C over -25 … +70 °C
(±0.27 °F over -13 … +158 °F)
One year accuracy 1) ±0.20 °C over +20 … +30 °C
(±0.36 °F over +68 … +86 °F)
±0.25 °C over -25 … +70 °C
(±0.45 °F over -13 … +158 °F)
Resolution 0.02 °C at +25 °C (0.04 °F at +77 °F)
“V” Range External Probe
Operating/storage range -95 … +95 °C (-139 … +203 °F)
Initial accuracy 1) ±0.20 °C over -90 … -40 °C
(±0.36 °F over -130 … -40 °F)
One year accuracy 1) ±0.25 °C over -90 … -40 °C
(±0.45 °F over -130 … -40 °F)
Resolution 0.02 °C at -80 °C (0.04 °F at -112 °F)
Calibrated measurement range -90 … -40 °C (-130 … -40 °F)