Thermocouple Extension Cable – Ninomiya FEP 1-Pair (Round Type)

Features

2 elemental compensating wires are insulated with FEP separately, stranded together with inclusion, shielded with tin-coated annealed copper wires (B), coated with FEP, and braided with stainless wires (C) for protection at the outermost.

Enquiry

2 elemental compensating wires are insulated with FEP separately, stranded together with inclusion, shielded with tin-coated annealed copper wires (B), coated with FEP, and braided with stainless wires (C) for protection at the outermost.

Specification

Parts No. Construction No. of pairs Conductor Insulation OD of pair mm OD of cabling mm Shield
thickness
mm
Sheath
thickness
mm
Finished
OD
mm
Standing
No./mm
OD
mm
Thickness
mm
OD
mm
12/0.18x1P □X-6F=FFR A 1 12/0.18 0.7 0.25 1.2 2.4 0.3 3.1
12/0.18x1P □X-6F-IS=FFR B 1 12/0.18 0.7 0.25 1.2 2.4 0.3 0.3 3.7
12/0.18x1P □X-6F-SOS=FFR C 1 12/0.18 0.7 0.25 1.2 2.4 0.3 0.3 3.7
7/0.3x1P □X-6F=FFR A 1 7/0.3 0.9 0.25 1.4 2.8 0.3 3.5
7/0.3x1P □X-6F-IS=FFR B 1 7/0.3 0.9 0.25 1.4 2.8 0.3 0.3 4.1
7/0.3x1P □X-6F-SOS=FFR C 1 7/0.3 0.9 0.25 1.4 2.8 0.3 0.3 4.1
20/0.18x1P □X-6F=FFR A 1 20/0.18 1.0 0.25 1.5 3.0 0.3 3.7
20/0.18x1P □X-6F-IS=FFR B 1 20/0.18 1.0 0.25 1.5 3.0 0.3 0.3 4.3
20/0.18x1P □X-6F-SOS=FFR C 1 20/0.18 1.0 0.25 1.5 3.0 0.3 0.3 4.3
30/0.18x1P □X-6F=FFR A 1 30/0.18 1.2 0.25 1.7 3.4 0.35 4.2
30/0.18x1P □X-6F-IS=FFR B 1 30/0.18 1.2 0.25 1.7 3.4 0.3 0.35 4.8
30/0.18x1P □X-6F-SOS=FFR C 1 30/0.18 1.2 0.25 1.7 3.4 0.35 0.3 4.8
7/0.45x1P □X-6F=FFR A 1 7/0.45 1.35 0.3 1.95 3.9 0.4 4.8
7/0.45x1P □X-6F-IS=FFR B 1 7/0.45 1.35 0.3 1.95 3.9 0.3 0.4 5.4
7/0.45x1P □X-6F-SOS=FFR C 1 7/0.45 1.35 0.3 1.95 3.9 0.4 0.3 5.4
4/0.65x1P □X-6F=FFR A 1 4/0.65 1.57 0.3 2.17 4.34 0.4 5.2
4/0.65x1P □X-6F-IS=FFR B 1 4/0.65 1.57 0.3 217.00 4.34 0.3 0.4 5.8
4/0.65x1P □X-6F-SOS=FFR C 1 4/0.65 1.57 0.3 2.17 4.34 0.4 0.3 5.8
7/0.65x1P □X-6F=FFR A 1 7/0.65 1.95 0.3 2.55 5.1 0.4 6.0
7/0.65x1P □X-6F-IS=FFR B 1 7/0.65 1.95 0.3 2.55 5.1 0.3 0.4 6.6
7/0.65x1P □X-6F-SOS=FFR C 1 7/0.65 1.95 0.3 2.55 5.1 0.4 0.3 6.6

Please fill in □ with a type (symbol) of a compensating cable to order.
We also manufacture outer shields for tin-coated annealed copper wires (OS). Please contact us with any requests.
We also manufacture multi-objective round type FEP insulated, FEP sheath compensating cables.

Download

Ninomiya FEP 1-Pair (Round Type) – Thermocouple Extension Cable-DpstarGroup

Reviews

There are no reviews yet.

Be the first to review “Thermocouple Extension Cable – Ninomiya FEP 1-Pair (Round Type)”

Your email address will not be published. Required fields are marked *