Single Phase Power Regulator – Shimaden PAC27 Series

Features

  • Phase Angle or Cycle Operation Zero Voltage Switching
  • Current Capacity: 20, 30, 45, 60, 80, 100A
  • Power Supply: 100~120/200~240V AC
  • On the condition that the product is used with a noise filter as specified by SHIMADEN, the CE safety standard (EMC Directive) shall be satisfied. *This applies to instance where the apparatus employs the phase angle control system or when the cycle operation zero-voltage switching system is utilized.
  • As we attach importance to safety aspects, the instrument has a number of alarm circuits including a built-in voltage feedback circuit as a standard function.
  • If you select the current or the voltage control system, or the voltage square switching control system from the optional functions, control of special types of heaters and transformer loading is possible.
Enquiry

For phase control system, constant voltage feedback control is equipped as standard. Space saving type single-phase power regulator with a wide selection of additional optional functions available. Control achieved under joint use with matching transformer is also available for various usages such as control of heater having alloy, graphite, silicon carbide or pure metal system as its heating element. *2 Application of CE marking is also available by jointly using the regulator with designated noise filter.

Specification

Control element configuration Thyristor (SCR) x 2 Anti-parallel connection
Power supply 100~110V, 110~120V, 200~220V, 220~240V AC
±10% 50/60 Hz
Rated frequency Common to 50/60Hz
Current capacity 20, 30, 45, 60, 80, 100A
Control input signal  
Current 4~20 mA DC / Receiving impedance: 100Ω
Voltage 1~5 V DC / Input impedance: 200kΩ minimum
Others Voltage, current signal
Contact No-voltage contact signal
Power Adjuster Voltage and current input types – Internal power adjuster is equipped on standard basis.
External power adjuster is mountable at option.
Element protection system Electronic overcurrent gate breaking circuit (when in action, alarm is output.)
Rapid fuse (option) (Upon fuse breaking, alarm is output.)
Alarm action When overcurrent gate breaking circuit is in action, when rapid fuse breaks, when thyristors are overheated, when shorting of thyristors is detected, when current flows across alarm output terminals (AL1 and AL2) (contact 240V AC, 1A)
Additional functions (Common options)
Rapid fuse with alarm output
External power Adjustment functions External power
Manual power
High/low power
High power
Low power
External power + manual power
Heater break alarm To be set at 0 to 100% of rated current
Operating environment
Ambient temperature range between -10 and 50°C
Ambient humidity range 90% RH maximum with no dew condensation
Storage temperature between -20 and 65°C
Applicable standards
Safety IEC 1010-1
EMC EMI (emission) EN55011 class A, Group 1
EMS (immunity) EN50082-2 on condition that designated noise filter is used.
Insulation resistance/dielectric strength  
Insulation resistance 500VDC 20MΩ minimum between power supply terminal and chassis
Dielectric strength 2000VAC/min. between power supply terminal and chassis
2300VAC/min. between power supply terminal and control input

Ordering Information

 

Phase Angle Control (PAC27P)

ITEMS CODE SPECIFICATIONS
SERIES PAC27P Phase Angle Control Single Phase Power Regulator
Control Input 2 Contact
3 1~5V DC Input Resistance: 200kΩ min.
4 4~20mA DC Receiving Resistance: 100Ω
6 0~10V DC Input Resistance: 200kΩ min.
9 Others (Please consult before ordering)
Power Supply 13- 100~110V AC±10%, 50 / 60Hz
14- 110~120V AC±10%, 50 / 60Hz
15- 200~220V AC±10%, 50 / 60Hz
16- 220~240V AC±10%, 50 / 60Hz
Current Capacity 020 20A
030 30A
045 45A
060 60A
080 80A
100 100A
Feedback Function 0 Constant Voltage Control (standard feature)
1 Constant Current Control
2 Constant Power Control
3 Power linear Control
Current Limit Function 0 None
1 With
N None (Internal installation as standard)
External Power Adjuster Contact Input P External power adjuster
B Base (low) power adjuster
H High/Low power adjuster
Current/Voltage Input P External power adjuster
M Manual power adjuster
W External power + Manual power
Heater Break Alarm 0 Without
1 With
Rapid Fuse 0 Without
1 With
Remark 0 Without
9 With (Please consult before ordering.)

 

Cycle Operation Zero-voltage Switching (PAC27C)

ITEMS CODE SPECIFICATIONS
SERIES PAC27C- Zero Voltage Switching Single Phase Power Regulator
Control Input 2 Contact
3 1~5V DC Input Resistance: 200kΩ min.
4 4~20mA DC Input Resistance: 100Ω
6 0~10V DC Input Resistance: 200kΩ min.
9 Others (Please consult before ordering)
Power Supply 13- 100~110V AC±10%, 50 / 60Hz
14- 110~120V AC±10%, 50 / 60Hz
15- 200~220V AC±10%, 50 / 60Hz
16- 220~240V AC±10%, 50 / 60Hz
Current Capacity 020 20A
030 30A
045 45A
060 60A
080 80A
100 100A
N None (Internal installation as standard)
External Power Adjuster Contact Input P External power adjuster
B Base (low) power adjuster
H High/Low power adjuster
Current/ Voltage Input P External power adjuster
M Manual power adjuster
W External power + Manual power
Heater Break Alarm 0 Without
1 With
Rapid Fuse 0 Without
1 With
Operating Output Indicator 0 Without
1 With (0-1mA DC, 0-100%scale)
Remark 0 Without
9 With (Please consult before ordering.)

 

Download

Shimaden PAC27 Series – Single Phase Power Regulator-DpstarGroup

Reviews

There are no reviews yet.

Be the first to review “Single Phase Power Regulator – Shimaden PAC27 Series”