Air | Gas | Mould
Tubular Heater
Bundle Heater
Finned Heater
Ducting Heater
PTC Heater
Anti Condensation Heater
Air Immersion Heater
Cartridge Heater
Silicon Carbide (SIC) Heater
Ceramic Bobbin Heater
Pencil Heater
Ceramic Fiber Heater
Flexible Silicone Rubber Heater
Air Circulation Heater
Hot Air Blower
Ceramic Infrared Heater
Quartz Infrared Heater
Band Heater
Ceramic Band Heater
Strip Heater
Cast-In Heater
Mineral Insulation Heater
Halogen Infrared Heater
Black Infrapara Heater
Infrared Silica Quartz Heater
Liquid
Immersion Heater
Teflon Heater
Inline Circulation Heater
Bobbin Heater
Tank Heater
Drum Heater
Jacket Heater
Explosion Proof Heater
Defrost Heater
Specialty Heating + Controls
Heat Trace
Control Panel & System Solutions
Industrial Hot Water Calorifier
Industrial Hot Water System
Electric Heater Steam Boiler
Oil Flushing Skids
Thermal Fluid Analysis
Heat Tape/Heated Sample Lines
Heated Hoses
Flexible Ceramic Heating Pads
Explosion Proof Air Heater
Explosion Proof Duct Heater
Explosion Proof Immersion Heater
Explosion Proof Line Heater
Explosion Proof Process Heater
Oven | Furnace
Thermocouple
RTD
Sanitary Probe
Platinium Curve Rigid Averaging
Cable Thermocouple
MI Thermocouple
HVAC Temperature Sensor
Handheld Probe
Wireless Temperature Transmitter
Green Mark Precision Temperature Sensor
Thermocouple Accessories
Thermowell
Temperature | Humidity | Dew Point
Temperature Controllers
Indicator
Transmitters
Data Logger
Temperature Gauges/Thermometer
Refrigeration
Thermostats
Handheld | Infrared | Thermal
Water Activity
Dehumidifiers | Humidifiers | Air Purifier
Thermocouples
RTD | PT100 Sensors
ATEX thermocouples
Thermowells
Ceramic Rollers
Calibration
Pressure
Pressure Transducers | Transmitters
Differential Pressure Transmitter
Pressure Gauges
Pressure Switches
Accessories
Level
Float Switch
Hydrostatic Level Probe
Level Switches & Transmitters
By-pass Level Transmitter
Capacitance Level Switch
Magnetic Level Sensor
Ultrasonic Level Sensor
Vibrating Level Switch
Air | Gas | Liquid Flow
Air Flow/Air Velocity Meter
Variable Area Flow Meter
Electromagnetic Flow Meters
Sanitary Magnetic Flow Meter
Positive Displacement Flow Meter
Insertion Magnetic Flow Meter
Liquid Turbine Flow Meter
Coriolis Mass Flow Meter
Ultrasonic Flow Meter
Vortex Flow Meter
Gas Roots Flow Meter
Gas Turbine Flow Meter
Oval Gear Flow Meter
Fluorescence Dissolved Oxygen
Recorder
SSR & Power Regulator
Signal Conditioners & Isolators
Power Supply
Communication Products & Converters
Control Components
- Sensors
- Temperature Controller
- Timer / Counter
- Indicator
- Switches
- Terminal Block / Buzzer
- Signal Light
Frequnecy Inverter | Drive
Thermocouple Cable
Extension Cable
Heat Resistant Cable
Power/Instrument/Control Cable
Braided Screen Cable
Solar Cable
Low Voltage Cable
LK Instrumentation Cable
Offshore Cable
Control Cable
Marine Cable
Air-Operated Double Diaphragm Pumps
Control and Measuring Instruments
Motor Driven Pumps
Solenoid Dosing Pumps
Mobile Safety / Ex-Proof Smartphone
Products for Automotive Industry
Test Instruments
Wireless Sensor, Transmitters, Receivers, Meter & Controllers
The design principle and material selection of the diaphragm pressure gauges allow them to meet the stringent demands occurring above all in the chemicals and petrochemicals industries. Special corrosion resistant materials protect the wetted parts in service with chemically aggressive media. Open process connections ensure that the gauges are easy to clean with highly viscous or crystallizing process media, thus guaranteeing process reliability.
The diaphragm system makes the gauges extensively insensitive to vibration or jarring, and produces a high level of overpressure protection and actuating force. As a result of the high actuating forces, diaphragm pressure gauges are particularly suitable for connection of electric alarm contacts. Electric alarm contacts open and close circuits in response to the position of the pressure gauge pointer.
Magnetic snap-action electric alarm contacts are predominantly used in adverse operating conditions. The high contact pressure and the selection of various contact materials result in reliable and cost-effective solutions, above all when high currents have to be switched. Signal output can however take place slightly in advance of or lagging slightly behind the motion of the actual value pointer. If the electrical switching capacities of the alarm contacts are exceeded or not reached, a relay is to be used to provide an appropriate current rating.
Inductive electric alarm contacts have an almost unlimited service life, as the signal is switched without physical contact. Closing or opening takes place without any feedback effect on the measuring system, precluding any signal lead or lag. A corresponding control unit is always required for operation. Units with inductive contacts may be operated in areas with potentially explosive atmospheres, assuming compliance with existing specifications.
Tecsis P2431-P2433-P2451-P2453 – Mechanical Pressure Gauges – Corrosion-Resistance-DpstarGroup
There are no reviews yet.
Your email address will not be published. Required fields are marked *
Your review *
Name *
Email *
Save my name, email, and website in this browser for the next time I comment.
Product Enquiry
Your Name (required)
Your Company Name (required)
Your Email (required)
Your Contact No
Product Name
From where you know about us Google SearchPaid SearchSocial MediaLinkedinFacebookEmail MarketingReferral
Your Message