Air | Gas | Mould
Tubular Heater
Bundle Heater
Finned Heater
Ducting Heater
PTC Heater
Anti Condensation Heater
Air Immersion Heater
Cartridge Heater
Silicon Carbide (SIC) Heater
Ceramic Bobbin Heater
Pencil Heater
Ceramic Fiber Heater
Flexible Silicone Rubber Heater
Air Circulation Heater
Hot Air Blower
Ceramic Infrared Heater
Quartz Infrared Heater
Band Heater
Ceramic Band Heater
Strip Heater
Cast-In Heater
Mineral Insulation Heater
Halogen Infrared Heater
Black Infrapara Heater
Infrared Silica Quartz Heater
Liquid
Immersion Heater
Teflon Heater
Inline Circulation Heater
Bobbin Heater
Tank Heater
Drum Heater
Jacket Heater
Explosion Proof Heater
Defrost Heater
Specialty Heating + Controls
Heat Trace
Control Panel & System Solutions
Industrial Hot Water Calorifier
Industrial Hot Water System
Electric Heater Steam Boiler
Oil Flushing Skids
Thermal Fluid Analysis
Heat Tape/Heated Sample Lines
Heated Hoses
Flexible Ceramic Heating Pads
Explosion Proof Air Heater
Explosion Proof Duct Heater
Explosion Proof Immersion Heater
Explosion Proof Line Heater
Explosion Proof Process Heater
Oven | Furnace
Thermocouple
RTD
Sanitary Probe
Platinium Curve Rigid Averaging
Cable Thermocouple
MI Thermocouple
HVAC Temperature Sensor
Handheld Probe
Wireless Temperature Transmitter
Green Mark Precision Temperature Sensor
Thermocouple Accessories
Thermowell
Temperature | Humidity | Dew Point
Temperature Controllers
Indicator
Transmitters
Data Logger
Temperature Gauges/Thermometer
Refrigeration
Thermostats
Handheld | Infrared | Thermal
Water Activity
Dehumidifiers | Humidifiers | Air Purifier
Thermocouples
RTD | PT100 Sensors
ATEX thermocouples
Thermowells
Ceramic Rollers
Calibration
Pressure
Pressure Transducers | Transmitters
Differential Pressure Transmitter
Pressure Gauges
Pressure Switches
Accessories
Level
Float Switch
Hydrostatic Level Probe
Level Switches & Transmitters
By-pass Level Transmitter
Capacitance Level Switch
Magnetic Level Sensor
Ultrasonic Level Sensor
Vibrating Level Switch
Air | Gas | Liquid Flow
Air Flow/Air Velocity Meter
Variable Area Flow Meter
Electromagnetic Flow Meters
Sanitary Magnetic Flow Meter
Positive Displacement Flow Meter
Insertion Magnetic Flow Meter
Liquid Turbine Flow Meter
Coriolis Mass Flow Meter
Ultrasonic Flow Meter
Vortex Flow Meter
Gas Roots Flow Meter
Gas Turbine Flow Meter
Oval Gear Flow Meter
Fluorescence Dissolved Oxygen
Recorder
SSR & Power Regulator
Signal Conditioners & Isolators
Power Supply
Communication Products & Converters
Control Components
- Sensors
- Temperature Controller
- Timer / Counter
- Indicator
- Switches
- Terminal Block / Buzzer
- Signal Light
Frequnecy Inverter | Drive
Thermocouple Cable
Extension Cable
Heat Resistant Cable
Power/Instrument/Control Cable
Braided Screen Cable
Solar Cable
Low Voltage Cable
LK Instrumentation Cable
Offshore Cable
Control Cable
Marine Cable
Air-Operated Double Diaphragm Pumps
Control and Measuring Instruments
Motor Driven Pumps
Solenoid Dosing Pumps
Mobile Safety / Ex-Proof Smartphone
Products for Automotive Industry
Test Instruments
Wireless Sensor, Transmitters, Receivers, Meter & Controllers
Through our deep knowledge and experience, we are able to supply electrical heat tracing systems and solutions to achieve both dynamic heat up and temperature maintenance applications in Oil and Gas, Palm Oil, Food Industry, and others. We understand your requirements and we are specialists in Electrical Heat Tracing solutions and provide reliable systems and solutions. Dpstar is responsible, trustworthy, and accountable you can count on.
Snow-clearing by heating cables on roofs and access ramps requires the implementation of a system to optimize energy consumption. Dpstar provides a hygrothermostat which controls the outside temperature and the presence of humidity thanks to two sensors. This regulation system limits the energy needed for the efficiency of your installations and extend the lifetime of your heating elements.
The FX/CDM1 A hygrothermostat permanently checks for the presence of snow or black ice in gutters or access ramps. The heating cables are powered according to the outside temperature and the presence of humidity. The energy required is calculated by an interval timer switch.
Electronic regulator alone: FX/CDM1 A • Power supply: 230 V. • Current rating: 6 A. • Fits to DIN rail. • Dimensions: 85 x 53 x 65 mm (3 modules).
External temperature sensor FX/CDM/SENSOR • Type : CTN 1000 Ohms at 25°C. • Dimensions : Box 50 x 50 x 35 mm. • Power supply : By standard 2 conductor cable, (not supplied)from the electronic box to the sensor terminals (50 m maximum).
External humidity sensor • Capacitive type. • Power supply: by 4 conductor cable from the electronic box to the sensor (5 m long, can be extended up to 50 m). • Heating: When it freezes, the sensor is automatically heated to melt the snow on the electrodes. • FX/CDM/SONDENEIGE: Box 60 x 15 x 15 mm + 2 electrodes 150 mm length in the extension. • FX/CDM/SONDEPARKING dimensions 60 x 60 x 35 mm.
FX/BOITIER option • IP 54 box (195 x 115 x 110 mm) for hygrothermostat.
°C Temperature below which the regulator comes into operation. Δt Zone in which the regulator operates as an energy dispenser proportional to needs.
Example: with “°C” = + 5°C and “t” = 10°C, if outside temperature: + 5°C : 0 % of energy 0°C : 50 % of energy – 5°C : 100 % of energy
“T min” Time Base This is the period of a cycle energised and de-energised in the operation sequence. Time can be set from 30s to 10 min. Example with 40 % of energy:
“SEN” Sensitivity of the humidity sensor This setting makes it possible to vary the sensititvity of the snow detection circuit. Value “1“ corresponds to the greatest sensitivity to humidity.
There are no reviews yet.
Your email address will not be published. Required fields are marked *
Your review *
Name *
Email *
Save my name, email, and website in this browser for the next time I comment.
Product Enquiry
Your Name (required)
Your Company Name (required)
Your Email (required)
Your Contact No
Product Name
From where you know about us Google SearchPaid SearchSocial MediaLinkedinFacebookEmail MarketingReferral
Your Message