This Slim-shaped Plug-in Isolated Dual points Alarm Setter, CP3705 functions to generate two independent relay contact ON/OFF outputs by comparing high level DC input signal with two pre-set trip points (higher and lower limits).
Alarm Setter (Dual Points) – Shimaden CP3705 Series
Features
- Slim-shaped plug-in converter with isolated single/dual- output
- DIN Rail mounting or Lateral mounting
- Power supply 100 – 240V AC or 24V DC
- Moisture-proof coating is applied as standard.
- CE marking applied (applicable standard: EMC: EN61326-1)
Specification
Input | DC voltage or DC current (see ordering code) | |||||||||||||
Input resistance | Voltage input: 1MΩmin. (1MΩ when power failure/constant input) | |||||||||||||
Current input: 250Ω | ||||||||||||||
Input tolerable range | Voltage input: 30V DC | |||||||||||||
Current input:40mA DC | ||||||||||||||
Alarm action method | High/Low Limit, High/High Limit, Low/Low Limit | |||||||||||||
Alarm setting method | By front rotary switch | |||||||||||||
Alarm setting range | 0 – 99% of input signal | |||||||||||||
Alarm setting resolution | 1%FS | |||||||||||||
Alarm setting accuracy | ±0.5%FS | |||||||||||||
Alarm output | Relay contact 2 outputs (c contact) | |||||||||||||
Alarm action hysterisis | 1.0% ±0.3% FS | |||||||||||||
Contact capacity | 125V AC 5A, resistive load | |||||||||||||
Conversion accuracy | Within ±0.1% at 25±5°C | |||||||||||||
Conversion output | DC voltage, current (see ordering code) | |||||||||||||
Input response speed | 150m sec. max. (0-90%) at 100% step input | |||||||||||||
Limitation of relay action | Relay starts to action about 2 seconds after the power is turned ON. | |||||||||||||
Power supply | 100 – 240V AC ±10% or 24V DC±10% | |||||||||||||
Power consumption | 5vA max. at 100-240V AC | |||||||||||||
2W max. at 24V DC | ||||||||||||||
Operating ambient temperature | -5 – 55°C | |||||||||||||
Operating ambient humidity | 5 – 90%RH (No dew condensation) | |||||||||||||
Stock temperature | -10 – 60°C | |||||||||||||
Isolation resistance | 100M Ω min. at 500V DC, between input, out 1, out 2, power supply and ground terminals | |||||||||||||
Dielectric strength | 1 minutes at 2000V AC, between input, out 1, out 2, power supply and ground terminals | |||||||||||||
1 minutes at 500V AC, between out 1 and out 2 | ||||||||||||||
Materials | Housing: ABS resin (UL94V-0) | |||||||||||||
Terminal block: PBT resin (UL94V-0) | ||||||||||||||
Terminal block cover: PC resin (UL94V-2) | ||||||||||||||
Din-rail stopper: PP resin (UL94-HB) | ||||||||||||||
External dimensions | 88 (H) x 29 (W) x D125 (H)mm | |||||||||||||
Weight | Main body: 130g max. | |||||||||||||
Terminal block: 80g max. |
Ordering Information
ITEMS | CODE | SPECIFICATIONS | ||||||||||
Series | CP3705- | Alarm Setter (Dual Points) | ||||||||||
Input | 1 | 0 – 5V DC | ||||||||||
4 | 0 – 10V DC | |||||||||||
5 | 1 – 5V DC | |||||||||||
6 | 4 – 20mA DC | |||||||||||
9 | Others (Please consult before ordering.) | |||||||||||
Alarm Action | 03 | High/Low Limit Alarm | ||||||||||
07 | Low/Low Limit Alarm | |||||||||||
08 | High/High Limit Alarm | |||||||||||
Power Supply | 90- | 100 – 240V AC ±10% 50/60Hz | ||||||||||
08- | 24V DC ±10% | |||||||||||
Remarks | 0 | Without | ||||||||||
9 | With (Please consult before ordering.) |