ENVIRONMENTAL CONDITIONS |
Operating temperature |
-40°C to +85°C |
Calibration temperature |
20…28°C |
Relative humidity |
< 95% RH (non-cond.) |
Protection degree (encl./terminal) |
IP68 / IP00 |
MECHANICAL SPECIFICATIONS |
Dimensions |
Ø 44 x 20.2 mm |
Weight approx. |
50 g |
Wire size |
1 x 1.5 mm2 stranded wire |
Screw terminal torque |
0.4 Nm |
Vibration |
IEC 60068-2-6 |
2…25 Hz |
±1.6 mm |
25…100 Hz |
±4 g |
COMMON SPECIFICATIONS |
Supply |
|
Supply voltage |
8.0…35 VDC |
Internal power dissipation |
25 mW…0.8 W |
Response time |
|
Response time (programmable) |
0.33…60 s |
Voltage drop |
8.0 VDC |
Warm-up time |
5 min. |
Programming |
Loop Link |
Signal / noise ratio |
Min. 60 dB |
Accuracy |
Better than 0.1% of sel. range |
Signal dynamics, input |
19 bit |
Signal dynamics, output |
16 bit |
Effect of supply voltage change |
< 0.005% of span / VDC |
EMC immunity influence |
< ±0.5% of span |
INPUT SPECIFICATIONS |
Common input specifications |
|
Max. offset |
50% of selected max. value |
Linear resistance input |
|
Measurement range / min. range (span) |
0…100 kΩ / 1 kΩ |
Cable resistance per wire (max.) |
100 Ω |
Sensor current |
> 25 μA, < 120 μA |
Effect of sensor cable resistance (3-wire) |
< 0.002 Ω / Ω |
Sensor error detection |
Yes |
Min. measurement range |
1 kΩ |
OUTPUT SPECIFICATIONS |
Current output |
|
Signal range |
4…20 mA |
Min. signal range |
16 mA |
Load (@ current output) |
≤ (Vsupply – 8) / 0.023 [Ω] |
Load stability |
≤ 0.01% of span / 100 Ω |
Sensor error indication |
Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale |
23 mA / 3.5 mA |
COMMON OUTPUT SPECIFICATIONS |
Updating time |
135 ms |
of span |
= of the presently selected range |
OBSERVED AUTHORITY REQUIREMENTS |
EMC |
2014/30/EU |
EAC |
TR-CU 020/2011 |
APPROVALS |
ATEX |
KEMA 10ATEX0004 X |
IECEx |
DEK 13.0036X |
INMETRO |
DEKRA 16.0014 X |
DNV-GL Marine |
Stand. f. Certific. No. 2.4 V1-7-2 |