ACI Platinum RTD Bendable Copper Averaging

Features

  • Copper sensing element with Etched Teflon colored lead wires
  • The three-wire “-3W” option should be ordered when using with a 3-Wire temperature transmitter or sensor configuration on your building management system or PLC (Programmable Logic Controller).
  • These sensors are hermetically sealed to ensure that moisture and other contaminants won’t affect the reliability of the sensing element.
  • The copper averaging sensor includes a foam pad to seal the duct and dampen vibrations once installed.
  • The sensor length determined by the total cross sectional area of your duct.
  • Standard enclosure options include the “-GD” galvanized or “-PB” plastic enclosure with hinged cover.
  • Optional NEMA/IP rated weather proof enclosures and NIST Certicates are available as referenced in the ordering grid.
  • For higher accuracies, see the A/TTM1K (Matched) Averaging transmitter Product Data Sheet.
Enquiry

Automation Components, Inc. (ACI) creates, manufactures, and distributes building automation sensors for the heating, ventilation, and air conditioning (HVAC) Industry. Dpstar is ACI Authorised Distributor in Malaysia. Our product lines include Temperature Sensors, Relative Humidity Sensors, Current Sensors, Pressure Sensors, Gas Sensors, and Wireless Sensors.

The ACI Platinum Copper Averaging Series features a copper sensing element with Etched Teflon colored lead wires to differentiate the different sensor types. The three-wire “-3W” option should be ordered when using with a 3-Wire temperature transmitter or sensor configuration on your building management system or PLC (Programmable Logic Controller). The purpose of the 3rd wire is to compensate for external lead wire resistance that will affect your sensor output. ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using a Platinum RTD style sensor. The sensing element includes a continuous sensing element, which covers the entire length of the copper tube. This produces a better average temperature over the entire cross sectional area of your duct or unit when compared to a single point duct sensor or multi-point averaging sensor. These sensors are hermetically sealed to ensure that moisture and other contaminants won’t affect the reliability of the sensing element. The copper averaging sensor includes a foam pad to seal the duct and dampen vibrations once installed. The sensor length should be determined by the total cross sectional area of your duct. Standard enclosure options include the “-GD” galvanized or “-PB” plastic enclosure with hinged cover. Optional NEMA/IP rated weather proof enclosures and NIST Certicates are available as referenced in the ordering grid. For higher accuracies, see the A/TTM1K (Matched) Averaging transmitter Product Data Sheet.

Applications

  • Roof Top Units
  • Air Handlers
  • Monitoring Duct Supply/Discharge/Return/Mixed Air

The ACI Platinum RTD Copper Averaging Series is covered by ACI’s Five (5) Year Limited Warranty.

Specification

Sensor Type Thermistor
Sensor Curve Non-Linear NTC (Negative Temperature Coefficient)
Number Sensing Points One
Number Wires Two (Non-Polarity Sensitive)
Sensor Output @ 25°C (77°F) | (Standard Lead Wire Colors) A/1.8K: 1.8KΩ nominal | (Red/Yellow)
A/3K: 3KΩ nominal | (White/Brown)
A/AN (Type III): 10KΩ nominal | (White/White)
A/AN-BC: 5.238KΩ nominal | (White/Yellow)
A/CP (Type II): 10KΩ nominal | (White/Green)
A/CSI: 10KΩ nominal | (Green/Yellow)
A/10KS: 10KΩ nominal | (White/Blue)
A/10K-E1: 10KΩ nominal | (Gray/Orange)
A/20K: 20KΩ nominal | (Brown/Blue)
A/50K: 50KΩ nominal | (Brown/Yellow)
A/100KS: 100KΩ nominal | (Black/Yellow)
Accuracy 0-70ºC (32-158ºF) +/-0.2ºC (+/-0.36ºF) except A/10K-E1 Series: +/- 0.3ºC (+/-0.54ºF)
A/1.8K Series: +/- 0.5ºC @ 25ºC (77ºF) and (+/-1.0ºC) (+/-1.8ºF)
Stabilit Sensor Dependent; Contact ACI for more information on the sensor in question
Response Time (63% Step Change 10 Seconds nominal
Power Dissipation Constant 3 mW/ºC except A/1.8K Series: 1 mW/ºC | A/10K-E1 Series: 2 mW/ºC
Operating Temperature Range -40 to 150ºC (-40 to 302ºF)
Storage Temperature Range -40 to 85ºC (-40 to 185ºF)
Operating Humidity Range 10 to 95% RH, non-condensing
Probe Material 304 Stainless Steel
Standard Wire Lead Wire Insulation | Wire Rating: Etched Teflon (PTFE) Colored Leads | MIL-W-16878/4 (Type E)
Temperature Rating: -55°C (-67°F) to 200°C (392°F)
Conductor Material: Silver Plated Copper
Rated Application: Suitable for Indoor and Outdoor (wet) location. Oil, Moisture, Acids, Oils and Moisture Resistant
Lead Length | Conductor Size: 4”, 6” and 8” Probes: 14” (35.6 cm) | 12” and 18” Probes: 24” (61cm) | 22 AWG (0.65mm)
Plenum Wire Lead Wire Insulation | Wire Rating: CL2P: FEP (Fluorinated Ethylene Propylene) | TYPE CL2P – TYPE CMP 22 AWG (UL), C(UL) FEP/FEP E130356 ROHS
Temperature Rating: CL2P: -80°C (-112°F) to 150°C (302°F)
Conductor Material: CL2P: Tinned Copper
Rated Application: CL2P: Suitable for Indoor and Outdoor (wet) locations. Oil, Gas, Sunglight, Abrasion Acid Resistant
Product Dimensions | Probe Diameter See table on back of product data sheet | 0.250″ (6.35mm)
Product Weight 4″ = 0.028 lbs. (12.7g) | 6″ = 0.036 lbs. (16.3g) | 8″ = 0.044 lbs. (20g) |
12″ = 0.066 lbs. (29.9g) | 18” = 0.09 lbs. (40.8g)
Agency Approvals CE, RoHS2, WEEE

Download

ACI Platinum RTD Copper Averaging_DpstarGroup