ENVIRONMENTAL CONDITIONS |
Operating temperature |
-20°C to +60°C |
Storage temperature |
-20°C to +85°C |
Calibration temperature |
20…28°C |
Relative humidity |
< 95% RH (non-cond.) |
Protection degree |
IP20 |
Installation in |
Pollution degree 2 & meas. / overvoltage cat. II |
MECHANICAL SPECIFICATIONS |
Dimensions (HxWxD) |
109 x 23.5 x 104 mm |
Dimensions (HxWxD) w/ 4501/451x |
109 x 23.5 x 116 / 131 mm |
Weight approx. |
170 g |
Weight incl. 4501 / 451x (approx.) |
185 g / 200 g |
DIN rail type |
DIN EN 60715/35 mm |
Wire size |
0.13…2.08 mm2 AWG 26…14 stranded wire |
Screw terminal torque |
0.5 Nm |
Vibration |
IEC 60068-2-6 |
2…13.2 Hz |
±1 mm |
13.2…100 Hz |
±0.7 g |
COMMON SPECIFICATIONS |
Supply |
|
Supply voltage |
19.2…31.2 VDC |
Fuse |
400 mA SB / 250 VAC |
Max. required power |
≤ 1.1 W…≤ 1.3 W / ≤ 1.5 W…≤ 1.9 W (1 / 2 ch.) |
Max. power dissipation, 1 / 2 ch. |
≤ 1.2 W / ≤ 1.6…1.8 W |
Isolation voltage |
|
Test /working: Input to any |
2.6 kVAC / 300 VAC reinforced isolation |
Output 1 to output 2 |
1.5 kVAC / 150 VAC reinforced isolation |
Status relay to supply |
1.5 kVAC / 150 VAC reinforced isolation |
Auxiliary supplies |
|
NAMUR supply |
8 VDC / 8 mA |
Programming |
PR 45xx |
Response time for cable fault |
< 200 ms |
INPUT SPECIFICATIONS |
Sensor types |
NAMUR according to EN 60947-5-6 / mechanical contact |
Frequency range |
0…5 kHz |
Min. pulse length |
> 0.1 ms |
Input resistance |
Nom. 1 kΩ |
Trig level, signal |
< 1.2 mA, > 2.1 mA |
Trig level, cable fault |
< 0.1 mA, > 6.5 mA |
OUTPUT SPECIFICATIONS |
Relay output |
|
Max. switching frequency |
20 Hz |
Max. voltage |
250 VAC / 30 VDC |
Max. current |
2 AAC / 2 ADC |
Max. AC power |
500 VA / 60 W |
Status relay |
|
Max. voltage |
125 VAC / 110 VDC |
Max. current |
0.5 AAC / 0.3 ADC |
Max. AC power |
62.5 VA / 32 W |
NPN outputs |
|
Max. switching frequency |
5 kHz |
Min. pulse length |
> 0.1 ms |
Max. load, current / voltage |
80 mA / 30 VDC |
Voltage drop at 80 mA |
< 2.5 VDC |
OBSERVED AUTHORITY REQUIREMENTS |
EMC |
2014/30/EU |
LVD |
2014/35/EU |
ATEX |
2014/34/EU |
RoHS |
2011/65/EU |
EAC |
TR-CU 020/2011 |
EAC Ex |
TR-CU 012/2011 |
EAC LVD |
TR-CU 004/2011 |
APPROVALS |
ATEX |
KEMA 07ATEX0146 X |
IECEx |
KEM 06.0039X |
c FM us |
FM19US0055X / FM19CA0028X |
c UL us, UL 61010-1 |
E314307 |
c UL us, UL 913 |
E233311 (only 9202xxx-U9) |
EAC Ex |
RU C-DK.HA65.B.00355/19 |
DNV-GL Marine |
TAA00000JD |
ClassNK |
TA18527M |
SIL |
SIL 2 certified & fully assessed acc. to IEC 61508 |