ENVIRONMENTAL CONDITIONS |
Operating temperature |
-20°C to +60°C |
Storage temperature |
-40°C to +85°C |
Relative humidity |
< 95% RH (non-cond.) |
Installation in |
Pollution degree 2 & meas. / overvoltage cat. II |
MECHANICAL SPECIFICATIONS |
Dimensions (HxWxD) |
144 x 443 x 141 mm |
Wire size |
2.5 mm2 / AWG 12 (Supply 1 / 2 and status relay connectors) |
COMMON SPECIFICATIONS |
Supply |
|
Supply voltage |
20…31.2 VDC (24 DC nom.) |
Max. required power |
≤ 60 W |
Isolation voltage |
|
Isolation voltage, test / working |
500 VAC / 50 VAC (Basic isolation between supply 1 & 2 and status relay) |
Replaceable fuses |
Fuse F1 & F2: 3.15 A SB, 250 V, type TR5 |
OUTPUT SPECIFICATIONS |
Status relay |
|
Max. voltage |
32 V (Zone 2 / Div. 2 area) 42 V (Safe area) |
Max. current |
100 mA (Zone 2 / Div. 2 area) 100 mA (Safe area) |
OBSERVED AUTHORITY REQUIREMENTS |
EMC |
2014/30/EU |
EAC |
TR-CU 020/2011 |
APPROVALS |
UL |
UL 508 / C22.2 no. 14 |
ATEX |
DEKRA 13ATEX0136X |
IECEx |
DEK 13.0044X |
FM |
0003049918-C |
Reviews